The Diagnostic-menu of the GSM
flip-phone AEG Teleport TP 9082
(Type: HT 920)
![[DEUTSCHE VERSION]](deutsch.gif)
(Differences to the phone-type TP 9070 DTFX are very small)
Indication of the firmware-version:
Input of ###999 (and eventually pushing down the left softkey) shows
the actual firmware-version of the phone.
actual display for Teleport TP 9082 (scrolling):
Version:
8200404/16_0
Cal-Sect. 0: 53.1882.890.03
Cal-Sect. 1: GSM_970811
Cal-Sect. 2: 1601_74I_H20
Cal-Sect. 3: 1601_74I_H20
Cal-Sect. 4: GSM_970811
"Auto-Interogation is ON"
Selftest display "black display"
Selftest display "white display"
Audio-loop (to end press "OK")
To end all press "OK" now !
Latest official version is 1701 (e.g. Cal-Sect. 2).
Preparing for diagnostic-menu (= monitor-mode)
as following for these phones:
cellular flip-phone (GSM-900): Teleport TP 9040, TP 9050,
TP 9070 DTFX, TP 9080 / 9082
(GSM-1800): TP 1850, E-Plus AEG-compact, TP 1870 DTFX
TP 1880 /1882
and models looking identically than these (e.g. NorTel,
Matra or Sanyo, consider the referring pictures at the side !):
at memoryplace 99 (SIM-memory, phone memory does not exist)
fill in name FELDTEST. Number not necessary.
After that call this place one time (e.g. about search)
Now a new menu without a number exists over the first menu-point.
This ist the "diagnostic"-menu (= monitor-mode).
"up" = push one time the "up/down"-button at the left side of the phone up !
Diagnostic-function turning on:
Menu, up, ok, ok, ok, 1 (or ok)
then e.g.
C, 2 push for normal (= Idle) diag-mode (Layer1Info).
Diagnostic-function turning off:
Menu, up, ok, ok, ok, 2
IDLE - Display (three lines):
Example || meaning:
Row 1: |
I |
19 |
: |
31 |
R |
42 |
|| |
I |
BCCH |
: |
NCC & BCC |
R |
RxLev |
Row 2: |
L |
15 |
S |
15 |
F |
1257 |
|| |
L |
LinkCount |
S |
S/N Ratio |
F |
AFC-value |
Row 3: |
N |
100 |
: |
34 |
R |
22 |
|| |
N |
BCCH |
: |
NCC & BCC |
R |
RxLev |
I = Idle mode
BCCH xxx = Broadcast control channel serving cell
(xxx from 001 to 124) (in example 19).
NCC x = National color code
(in Germany 3 for D1 or 7 for D2) (in example 3).
BCC x =Base station color code
(in Germany x from 0 to 7) (in example 1).
!!!! NCC and BCC together are the BSIC = Base station identity code !!!!
RxLev xx = absolut Receive level
from 0 (= - 110 dBm) to 87 (= - 23 dBm) (xx in example 42 = - 68 dBm).
L xx = Link count
a kind of RadioLinkTimeout counter,
start counter is preset in the parameters of the base station;
if one block can not be decoded, one will be subtracted;
if the next block can be decoded, two will be added up to a maximum
level defined by the base station.
If the counter is zero, the connection will be interrupted
(in idle-mode with active SIM in the home-net 15).
(One block are four frames).
S xx = Signal to Noise Ratio in dB
(with good receive-level in home-net 15).
F xxxx = AFC (Automatic Frequency Control) value
digital control value for the frequency
(only 9070 DTFX since firmware-version 7207-1/DTFX).
The digital AFC-value shown on the display and the real
frequency-correction in Hz are attached through a nonlinear
signature-line. An example:
An increase about 1 in AFC-value means a difference
about 20 - 40 Hz (900 MHz), on DCS (1800 MHZ) it's twice the value.
N = Neighbour channels
scanning up to six neighbour channels
(example s.a.).
DEDICATED - Display (three lines):
Example || meaning:
Row 1: |
D |
19 |
: |
5 |
R |
41 |
Q |
0 |
|| |
D |
ARFCN |
: |
TS |
R |
RxLev |
Q |
Quality |
Row 2: |
L |
24 |
T |
2 |
X |
3 |
S |
15 |
|| |
L |
LinkCount |
T |
Tim.Adv. |
X |
act.TxPwr |
S |
S/N Ratio |
Row 3: |
N |
100 |
: |
34 |
R |
22 |
|
|
|| |
N |
BCCH |
: |
NCC & BCC |
R |
RxLev |
or: |
B |
19 |
: |
31 |
|
|
|
|
|| |
B |
BCCH |
: |
NCC & BCC |
D = Dedicated mode
ARFCN xxx = Absolute radio frequency channel number =
channel where your call works (xxx from 001 to 124) (in example channel 19).
(combination of TCH + SACCH or SDCCH + SACCH)
If there is an "H" displayed, frequency-hopping is used.
TS x = Time slot = time slot in which the phone is sending (x from 0 to 7) (in example 5).
RxLev xx = absolut Receive level
from 0 (= - 110 dBm) to 87 (= - 23 dBm) (xx in example 41 = -69 dBm).
Q x = Bit Error Rate (in example 0 = 0.2 %)
Q |
0 |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
BER |
0.2 % |
0.4 % |
0.8 % |
1.6 % |
3.2 % |
6.4 % |
12.8 % |
25.6 % |
L xx = Link count
a kind of RadioLinkTimeout counter,
start counter is preset in the parameters of the base station;
if one block can not be decoded, one will be subtracted;
if the next block can be decoded, two will be added up to a maximum
level defined by the base station.
If the counter is zero, the connection will be interrupted
(in dedicated-mode with active SIM in the home-net 24).
(One block are four frames).
T xx = Timing Advance
Dividing through 2 is distance to the BTS in km.
Or multiplicate the value with 547 m (a little bit more exact).
X xx = actual TxPwr
actual TxPower in dedicated mode, e.g.:
( X 0 |
43 dBm |
20 W ) |
( X 1 |
41 dBm |
12 W ) |
( X 2 |
39 dBm |
8 W ) |
( X 3 |
37 dBm |
5 W ) |
( X 4 |
35 dBm |
3.16 W ) |
X 5 |
33 dBm |
2 W |
X 6 |
31 dBm |
1.26 W |
X 7 |
29 dBm |
794 mW |
X 8 |
27 dBm |
501 mW |
X 9 |
25 dBm |
316 mW |
X 10 |
23 dBm |
199 mW |
X 11 |
21 dBm |
125 mW |
X 12 |
19 dBm |
79 mW |
X 13 |
17 dBm |
50 mW |
X 14 |
15 dBm |
32 mW |
X 15 |
13 dBm |
20 mW |
S xx = Signal to Noise Ratio in dB
a kind of S/N-counter
(with good receive-level in home-net 15).
N = Neighbour channels (BCCHs, see Idle-mode)
scanning up to six neighbour channels
(example s.a.).
B = as seventh display at "N" the first row from Idle mode (without RxLev):
BCCH : NCC & BCC (= BCCH of the Server Cell).
Other Displays (three lines):
A = Access
shows the access of the MS or BTS to the organization channels.
Accesses to the RACH and PCH.
P = Power Measurement
S = Synchronization
The menupoint "diagnostic":
Point 1, Settings:
has got the chapters
- 1 Diagmode: ON or OFF (default: OFF)
- 2 PeriodTime: a time period between 1 and 9 (default: 5).
With this you can change the switching period between standard- and
diagnostic-screen.
A number under three turns permanently on the diagnostic-screen.
Caution, after this you have to turn off BLIND the diagnostic-function !!!
And this counter determines the time of showing/scrolling the
neighbour channels in the Layer1Info and the display-actualisation-time.
- 3 Errlog clr: choosing this clears the Errlog-memory.
- 4 Errlog lev: choosing the Errlog-level.
These points (-3 and -4) have no effect for the user.
- 6 AutoInter: ON or OFF (Auto Interogate, default: ON)
Without function, works only with external PC-Program.
Point 2, Layer1Info is identical with IDLE- and DEDICATED-screen
(turn on from main-menu with menu, up, ok, 2 after activating the diagnostic-function)
Point 4, GenInfo shows information of the phone
actual display for Teleport TP 9082:
FW 8200404/16_0:
1601_74I_H20
FFFFFFFFFFFF
DSP 00613000
PCB Versions
188224004004
188231002002
Point 5, IMEI shows the serial number of the phone (IMEI)
Number of accesses since April `01 
© by Dirk Salva